The Aico Easi-fit technology Aico radiolink technology explained Aico Multi-sensor alarm Ei2110 Fire and smoke detectors Ei140 and Ei160 Aico system solutions for fire alarms systems More documentation about the fire alarms, fire detectors, standards and rules  
FireDetect.co.uk - fire detectors
submit
Aico Heat Alarms - fire or smoke alarms Introducing the Easi-Fit technology from Aico for the Aico fire and smoke alarms
Back Home, Fire Detectors
Ionisation fire and heat detectors
Heat detectors
Optical fire or heat detectors
The Easi-fit technology from Aico
Time and money saving, simple technology to install the smoke / heat / ionisation alarms from Aico - Easi-fit.
Contact us - Sparks Electrical Wholesalers Ltd, Archway, London
Fire detectors - more details Introducing the easi-fit technology from Aico

Easi-fit - easy to fit - Fire Alarms installation simple technology

Introducing the Easi-fit technology from Aico - easy-way-to-fit the Aico fire alarms, smoke alarms, heat alarms. It basically consists of three simple steps, as seen below. For more details about the functioning of the easi-fit technology, consult the design and description of the Aico Ei series fire alarms, and some its high quality features, or read more about it here.

Easi-fit technology installation guide - step 1

Easi-fit - Step 1
Screw the mounting plate supplied with the alarm to the ceiling during first fix. No separate enclosure is required.

Easi-fit technology installation guide - step 2

Easi-fit - Step 2
Wire up the terminals on the mounting plate and then clip on the protective cover.
 

Easi-fit technology installation guide - step 3

Easi-fit - Step 3
Slide the alarm into place. There's no need to wire up a separate lead and connector.
 

The Aico optical alarms
The optical sensors are more responsible to the smouldering fires producing large particle smoke, typical for... read more

The Aico ionisation alarms
The ionisation type sensors are a more sensitive class of sensors to the smoke that is almost invisible to the eye read more

The Aico heat alarms
The heat alarm are less likely to produce false alarms since they are less responsive to fire or smoke and more responsive to the rise of heat... read more


 
About the fire alarms and this website

Aico Easi-fit - Aico fire alarms installation technology - features

 

Heat detectors from Aico
Using a heat sensor, not so keen on the smoke or fire detection but on the rise ....


Aico CO detectors
The CO(Carbon Monoxide) is am insidous gas, a killer. It cannot be seen, smelled or tasted. The CO alarms ....


Smoke detectors Aico
The Aico smoke detectors are keen mainly to detect the smoke produced by ....

 
Aico Easi-fit technology - more about this simple technology

1. The Aico optical smoke chamber
Aico innovative design - easi fit - the optical smoke chamber Ei's unique large volume optical smoke chamber and sophisticated electronics have a proven track record of reliability and high efficiency detection.

Longevity and resistance to false alarms as well as reliable protection from electromagnetic interference has also been proven over many years.

2. The Smoke alarm Insect Screen
Aico innovative design - easi fit - the insect screen The Smoke Alarms are sophisticated electronic devices. Protection from external contamination is vital to maintain the fire detecting sensitivity of the product and to minimise false alarms. A fine mesh insect screen reduces false alarms caused by insect contamination and fibres, while still allowing free access of smoke to the sensor chamber. A dust cover is also provided for protection on site and prior to occupancy.

3. Test and Hush Button
Aico innovative design - easi fit - the test and hush button # The test and hush button provides false alarm control on all Easi-fit models.
# The test and hush button also provides a manual test function.

The test and hush button is used mainly with the Aico Ei 140 and Ei160RC models.

5. Indicating LEDs
Aico innovative design - easi fit - the indicating LEDs # Self monitoring and indicating LEDs and audible warning signals.
# Each alarm self tests every 40 seconds.
# Two separate LED indicators are used to indicate healthy mains supply, battery fault, alarm status and low cell/battery warning.

4. Rechargeable Cells

  • Ultra high performance vanadium pentoxide Lithium rechargeable cells are used in the Ei2110 Multi-Sensor, 160RC Series, 150 Series and RadioLINK bases.
  • These cells offer the best back-up possible and are proven to last a minimum of 10 years.
  • A precision charging circuit ensures peak cell efficiency at all times.
  • Cells provide up to six months back-up without mains power.

6. The Sounder

  • At 85dB(A) at 3 metres, the Aico ionisation, smoke, heat or fire alarms are loud.
  • The unique encased horn assembly has the piezo disc securely held with silicone mastic to prevent creepage and premature horn failure.
  • Additionally soldered contacts prevent failures due to corrosion and arcing associated with more commonly used pressure contacts.

Top

Easi-fit innovative design - some of the quality features

Fixed temperature fast response thermistor sensor
The Aico heat alarms feature a fixed temperature fast response thermistor sensor, making them ideal for protecting kitchens and garages.

A precision casing design resulted by the computer analysis
The computer analysis of the smoke flow results in a precision casing design (this allows fast access of smoke to the sensor, in Aico fire alarms).  

A high performance ionisation chamber - the ionisation alarms
The Aico ionisation alarms feature a high performance ionisation chamber that responds quickly to flaming fires. This was proven in millions of applications by a lot of tests.
Test, Hush and Fire Locate functions - allowed by the Ei2110 and the Ei160RC series
The Ei2110 Multi-Sensor and 160RC Series alarms allow Test, Hush and Fire Locate functions to be performed from an optional control switch mounted at an easily accessible height.
Battery back-up - Alkaline battery
The Alkaline battery back-up for the Aico Ei140 Series is designed to last up to 4 years in stand-by. Aico Ei160RC series uses Lithium cell with 10+ years. Top

Aico ionisation alarms - ionisation detectors from AicoIonisation Alarm

# Ionisation alarm specs
# Aico Ei141, Ei161RC
# RadioLINK connect
# Specifier or Contractor

Aico Heat alarms - heat detectors from AicoHeat Alarms

# Heat alarm features
# Aico Ei144, Ei164RC
# RadioLINK connect
# Specifier, Contractor

Aico optical alarms - optical detectors from AicoOptical Alarms

# Optical alarm specs
# Aico Ei146, Ei166RC
# RadioLINK connect
# Specifier, Contractor

Home | About Us | Aico heat alarm | Aico optical alarm | Aico ionisation alarm | Aico CO alarm | Contact Us | FAQ
Copyright © Sparks Electrical Wholesalers Ltd.
SparksDirect | Blog | Magnetic light | Lights | Dimmers | Metal switch | Lights Deals | Wireless alarm | Newlights
Back to the top of the page Back to the home page of the presentation website - fire detect.co.uk